Inspection Status: Partial Pass

Inspection History: COT - RSBU - Interior Shear Bracing 

Date Description Inspector Results Comments
03/03/2026 COT - RSBU - Interior Shear Bracing  Partial Pass 3-3-26: verified 5/8" type X drywall in between both units with screw spacing at 4" o.c. Along edges & 8" o.c. In the field. Pending installation of 5/8" Type X drywall at exterior side. Okay to continue construction at progress areas.
03/06/2026 COT - RSBU - Interior Shear Bracing  Partial Pass 3-6-26: okay to install exterior 5/8" drywall.
COT - RSBU - Interior Shear Bracing  Partial Pass 3-10-26: okay to install 5/8" drywall at exterior side. We will use this inspection to verify drywall screw prior to units being taped & textured.
03/16/2026 COT - RSBU - Interior Shear Bracing  Partial Pass 3/16/2026
Partial pass pending final drywall firewall inspection prior to tape/texture. Okay to proceed.
03/19/2026 COT - RSBU - Interior Shear Bracing  Passed 3/19/2026
Approved drywall, verified outside firewall at common wall.