Inspection Status: Partial Pass
Inspection History: COT - RSBU - Interior Shear Bracing
Permit Number - TC-MDP-1225-00768
Inspection Description - COT - RSBU - Interior Shear Bracing
Inspection Status - Partial Pass
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/03/2026 | COT - RSBU - Interior Shear Bracing | Partial Pass | 3-3-26: verified 5/8" type X drywall in between both units with screw spacing at 4" o.c. Along edges & 8" o.c. In the field. Pending installation of 5/8" Type X drywall at exterior side. Okay to continue construction at progress areas. | |
| 03/06/2026 | COT - RSBU - Interior Shear Bracing | Partial Pass | 3-6-26: okay to install exterior 5/8" drywall. | |
| COT - RSBU - Interior Shear Bracing | Partial Pass | 3-10-26: okay to install 5/8" drywall at exterior side. We will use this inspection to verify drywall screw prior to units being taped & textured. |