Inspection History Details
Inspection Status: Partial Pass
Inspection History: COT - RSBU - Interior Shear Bracing
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/03/2026 | COT - RSBU - Interior Shear Bracing | Partial Pass | 3-3-26: verified 5/8" type X drywall in between both units with screw spacing at 4" o.c. Along edges & 8" o.c. In the field. Pending installation of 5/8" Type X drywall at exterior side. Okay to continue construction at progress areas. | |
| 03/06/2026 | COT - RSBU - Interior Shear Bracing | Partial Pass | 3-6-26: okay to install exterior 5/8" drywall. | |
| COT - RSBU - Interior Shear Bracing | Partial Pass | 3-10-26: okay to install 5/8" drywall at exterior side. We will use this inspection to verify drywall screw prior to units being taped & textured. | ||
| 03/16/2026 | COT - RSBU - Interior Shear Bracing | Partial Pass | 3/16/2026 Partial pass pending final drywall firewall inspection prior to tape/texture. Okay to proceed. |
|
| 03/19/2026 | COT - RSBU - Interior Shear Bracing | Passed | 3/19/2026 Approved drywall, verified outside firewall at common wall. |