Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Partial Pass

Inspection History: COT - RSBU - Interior Shear Bracing 

Permit Number - TC-MDP-1225-00768

Inspection Description - COT - RSBU - Interior Shear Bracing 

Inspection Status - Partial Pass

Date Description Inspector Results Comments
03/03/2026 COT - RSBU - Interior Shear Bracing  Partial Pass 3-3-26: verified 5/8" type X drywall in between both units with screw spacing at 4" o.c. Along edges & 8" o.c. In the field. Pending installation of 5/8" Type X drywall at exterior side. Okay to continue construction at progress areas.
03/06/2026 COT - RSBU - Interior Shear Bracing  Partial Pass 3-6-26: okay to install exterior 5/8" drywall.
COT - RSBU - Interior Shear Bracing  Partial Pass 3-10-26: okay to install 5/8" drywall at exterior side. We will use this inspection to verify drywall screw prior to units being taped & textured.