Parcel: 141460050


Addresses:

7342 S DEMPSEY AV


Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Permit Number - TC-MDP-1224-01409

Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
11/12/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 11.12.2025
Missing HTT4s on SW11 interior shear wall, missing 3” washer plates on rear SW13 shear wall, missing (2) 2x8 header on north garage wall per plan, add anchors bolts as marked and add stud to north wall to girder floor truss as marked. NOTE: Stopped inspection, more items may be found - next inspection needs to walk upstairs and roof.
11/13/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 11/13/25 corrections made