Parcel: 141460080


Addresses:

7364 S DEMPSEY AV


Inspection Status: Not Ready

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Permit Number - TC-MDP-1224-01406

Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Inspection Status - Not Ready

Date Description Inspector Results Comments
08/28/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Not Ready Trades working in dwelling without the approval of the inspection. Materials are all over the floors. Provide a cleaning working environment prior to inspection. 8/28/2025
09/02/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required (with fee) 9.2.2025
Missing nails on hangar in garage, missing screws on belly band, missing nails on edge on face of garage, missing studs and H2.5’s on girder trusses. Workers on site with equipment. STOPPED INSPECTION, MORE ITEMS MAY BE FOUND. REINSPECTION FEE REQUIRED.
09/05/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 9.5.2025
Same items not corrected from prior 9.2.2025 inspection. Missing anchor bolts at front of garage per red markings, missing HTT4’s at interior wall near garage, ledger at porch entry missing nails and 2x4 high ledger is short, add 2 more 2x4s at entry (see red markings) for girder truss, missing anchor bolts in back patio as well as 2x8 header. Plan calls for hangar instead of beam in wall on back patio. STOPPED INSPECTION, MORE ITEMS MAY BE FOUND. NEXT FAILED INSPECTION WOULD REQUIRE FEE.
09/08/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 9.8.25
Corrections made as requested
Additional items corrected and verified via photograph
Proceed