Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Not Ready
Inspection History: COT - RSBU - Roof Nailing
Permit Number - TC-MDP-1224-01406
Inspection Description - COT - RSBU - Roof Nailing
Inspection Status - Not Ready
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/28/2025 | COT - RSBU - Roof Nailing | Not Ready | Trades working in dwelling without the approval of the inspection. Materials are all over the floors. Provide a cleaning working environment prior to inspection. 8/28/2025 | |
| 09/02/2025 | COT - RSBU - Roof Nailing | Re-inspection required | 9.2.2025 Per previous notes. |
|
| 09/05/2025 | COT - RSBU - Roof Nailing | Re-inspection required | 9.5.2025 Same items not corrected from prior 9.2.2025 inspection. Missing anchor bolts at front of garage per red markings, missing HTT4’s at interior wall near garage, ledger at porch entry missing nails and 2x4 high ledger is short, add 2 more 2x4s at entry (see red markings) for girder truss, missing anchor bolts in back patio as well as 2x8 header. Plan calls for hangar instead of beam in wall on back patio. STOPPED INSPECTION, MORE ITEMS MAY BE FOUND. NEXT FAILED INSPECTION WOULD REQUIRE FEE. |
|
| 09/08/2025 | COT - RSBU - Roof Nailing | Passed | 9.8.25 Corrections made as requested Additional items corrected and verified via photograph Proceed |