Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Permit Number - TC-MDP-1224-01402
Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/24/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 2.24.25 Anchor bolts shall be in the center 3rd of the plate Shot pin spacing may not exceed 24" at load bearing walls Shot pin spacing may not exceed 32" at non load bearing walls Add nails at all open cells at sole plate & 2nd floor STOPPED INSPECTION. ADDITIONAL ITEMS MAY BE ADDED |
|
| 07/25/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 7/25/25 Pass |