Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Permit Number - TC-MDP-1224-01402

Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
07/24/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 2.24.25
Anchor bolts shall be in the center 3rd of the plate
Shot pin spacing may not exceed 24" at load bearing walls
Shot pin spacing may not exceed 32" at non load bearing walls
Add nails at all open cells at sole plate & 2nd floor
STOPPED INSPECTION. ADDITIONAL ITEMS MAY BE ADDED
07/25/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 7/25/25
Pass