Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSPL - Rough Soil
Permit Number - TC-MDP-1224-01401
Inspection Description - COT - RSPL - Rough Soil
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/20/2025 | COT - RSPL - Rough Soil | Re-inspection required | 5-20-25, Underground plumbing shall not be supported by by rocks at any point. Remove all loose dirt from plumbing and joints. Trench shall be free of loose dirt, rocks, and any debris, see P2604.1 of the IRC for details. Also, a 12 inch clearance is required from potable water and the sewer-see P2906.4.1. | |
| 05/22/2025 | COT - RSPL - Rough Soil | Passed | 5/22/25 corrections made |