Inspection Status: Re-inspection required
Inspection History: COT - RSPL - Yard Water Line
Permit Number - TC-MDP-1224-01401
Inspection Description - COT - RSPL - Yard Water Line
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/20/2025 | COT - RSPL - Yard Water Line | Re-inspection required | 5-20-25, Underground plumbing shall not be supported by by rocks at any point. Remove all loose dirt from plumbing and joints. Trench shall be free of loose dirt, rocks, and any debris, see P2604.1 of the IRC for details. Also, a 12 inch clearance is required from potable water and the sewer-see P2906.4.1. | |
| 05/22/2025 | COT - RSPL - Yard Water Line | Passed | 5/22/25 corrections made |