Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
Permit Number - TC-MDP-1224-01400
Inspection Description - COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/01/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | Missing smoke detector in den/bedroom. Secure pex lines every 32” horizontally. 4’ vertical. Kitchen area. Add nail plates to electrical lines. Support abs pipes at every 4’. Strap abs pipes midway. Staple punctured abs pipe in great room area. Add support at abs above. Remove from gusset plate. Seal off chases. Flex is in the attic access. Electrical boxes not made up in attic. Seal all tears at duct. Missing smoke detector for East bedrooms. Tape electrical line and secure near landing. Bedroom 3 smokie to close to the wall. Secure primary condensation line. Receptacle in master bedroom exceeding 12’. Shower pan not on test. Stud shoes required at 2x4 plumbing wall in master bath. 7/1/2025 | |
| 07/11/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | Missing smoke detector in den/bedroom. Secure pex lines every 32” horizontally. 4’ vertical. Kitchen area. Add nail plates to electrical lines. Support abs pipes at every 4’. Strap abs pipes midway. Staple punctured abs pipe in great room area. Add support at abs above. Remove from gusset plate. Seal off chases. Flex is in the attic access. Electrical boxes not made up in attic. Seal all tears at duct. Missing smoke detector for East bedrooms. Tape electrical line and secure near landing. Bedroom 3 smokie to close to the wall. Secure primary condensation line. Receptacle in master bedroom exceeding 12’. Shower pan not on test. Stud shoes required at 2x4 plumbing wall in master bath. 7/1/2025 7/11/25: seal electrical chase at kitchen island, secure ABS off of 4-gang box at kitchen, ground all metallic boxes, secure condensate drain in wall, properly secure condensate drain in attic (continuous slope), nail plates required at marked locations up stairs for electrical, seal penetrations through vapor barrier at east bedroom,seal penetration through top plate at thermostat up stairs east bedroom, stud shoe required at master bathroom, seal mechanical chase in master closet, seal tears at flex in master closet chase, FHA PLATES required at dryer exhaust duct at top plate, support pex lines coming out of washer box, remove nm cable off of dryer vent duct in attic, |
|
| 07/16/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 7.16.25 Satisfactory corrections made |
|
| 07/17/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed |