Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Permit Number - TC-MDP-1224-01399
Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/16/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | Install guards at staircase, sister damaged studs at stairs and 2nd floor, add anchor bolts and shot pins at marked locations, add 3x3 washer plates at shear wall 11 or greater, missing a35 clips at stair stringers | |
| 07/17/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | Passed 7/17/25 corrections made |