Parcel: 141461630


Addresses:

9530 E WYNALDA DR


Inspection Status: Canceled

Inspection History: COT - RSBU - Roof Nailing 

Permit Number - TC-MDP-1224-01398

Inspection Description - COT - RSBU - Roof Nailing 

Inspection Status - Canceled

Date Description Inspector Results Comments
06/02/2025 COT - RSBU - Roof Nailing  Canceled 6/2/25
Canceled.
06/03/2025 COT - RSBU - Roof Nailing  Re-inspection required 6-3-25: add anchor bolt/washer garage shear was-anchor bolts to be placed at 17" o.c. Add shot pins to marked location, and nails along edges/joints at exterior rim board sheathing throughout including-see nail spacing for details and add nails where overpenetrated (cannot over penetrate more than 1/8").Upper floor: add nails at sill plate to decking-south shear wall, and nails to to shear wall base at north shear wall, and nails to sill plate to decking at marked locations-STOPPED INSPECTION -ADDITIONAL ITEMS MAY BE ADDED.
06/06/2025 COT - RSBU - Roof Nailing  Passed