Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/05/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | Shear wall 11 and greater require 3"x3" washer plates, shear wall 13 anchor bolts not per schedule, missing anchor bolts throughout, over penetrating nails at shear walls marked, sister damaged king stud at great room window. STOPPED INSPECTION MORE ITEMS MAY BE ADDED. | |
| 05/09/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 5/9/25 see previous notes | |
| 05/13/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required (with fee) | 5/13/25 Plans not on site when arrived had to wait for contractor to get them, damaged sister stud at great room window. First floor was covered in lathing. |
|
| 07/03/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 7/3/2025 approved per Damon Coons. |