Parcel: 141461570


Addresses:

9517 E MEOLA DR


Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Roof Nailing 

Permit Number - TC-MDP-1224-01396

Inspection Description - COT - RSBU - Roof Nailing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
05/05/2025 COT - RSBU - Roof Nailing  Re-inspection required Shear wall 11 and greater require 3"x3" washer plates, shear wall 13 anchor bolts not per schedule, missing anchor bolts throughout, over penetrating nails at shear walls marked, sister damaged king stud at great room window. STOPPED INSPECTION MORE ITEMS MAY BE ADDED.
05/09/2025 COT - RSBU - Roof Nailing  Re-inspection required 5/9/25 see previous notes
05/13/2025 COT - RSBU - Roof Nailing  Passed 5/13/25