Inspection History Details
Inspection Status: Not Ready
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/09/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Not Ready | Entire wall and door near staircase disconnected | |
| 05/12/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | Entire wall and door near staircase disconnected 5/12/25 1. Stairs not per plan, requires A34 clips at each stringer, requires 2x8 blocking at the top of the stairs. 2. LTP4's required in garage north and south shear walls. See detail 208. 3. Attic access compromised, hvac drain pan is encroaching into access. |
|
| 05/16/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 5/16/25 corrections made |