Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 140363920


Addresses:

6415 S AMBARELLA DR


Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - TC-MDP-1223-01895

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
01/26/2024 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required 1/26/24: MASA CLIP on south west end not properly fastened, Anchor bolts required 12" max from bottom plate edge missing throughout, anchor bolt spacing is greater than 6' on north side of home, STHD10 at garage not properly fastened, hangers missing at garage at trusses connecting to B01, SW11 calls for 3"x3" washers missing at multiple locations, SW11 Anchor bolt spacing is 23" o.c missing throughout, roofing missing nails in multiple locations.
01/29/2024 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required 1/26/24: MASA CLIP on south west end not properly fastened, Anchor bolts required 12" max from bottom plate edge missing throughout, anchor bolt spacing is greater than 6' on north side of home, STHD10 at garage not properly fastened, hangers missing at garage at trusses connecting to B01, SW11 calls for 3"x3" washers missing at multiple locations, SW11 Anchor bolt spacing is 23" o.c missing throughout, roofing missing nails in multiple locations.

1/29/24: roof nailing missing in multiple locations, SW11 requires anchor bolts with 3"x3" washer at 23" O.C, anchor bolts at SW11 must be properly fastened (multiple washers are lose which indicates anchor bolts not properly fastened).
01/30/2024 COT - RSBU - Exterior Clips/Sheathing  Canceled Cancelled per Karl.
01/31/2024 COT - RSBU - Exterior Clips/Sheathing  Passed 1/31/24: all corrections made