Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Passed
Inspection History: COT - RSEL - Electrical Underground
Permit Number - TC-MDP-1223-01892
Inspection Description - COT - RSEL - Electrical Underground
Inspection Status - Passed
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/26/2024 | COT - RSEL - Electrical Underground | Passed | Footing is properly dug, forms are set, post tension cabling is installed per plans, rebar reinforcement is installed per plans and specifications, plumbing pipes are properly wrapped to protect against concrete damage, black box block outs are installed for shower and bathtub pipes, under slab electrical conduit is installed for kitchen island, and Ufer ground is properly installed and attached to rebar reinforcement. Okay to pour concrete for slab and footings. |