Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Passed
Inspection History: COT - RSBU - Exterior Clips/SheathingÂ
Permit Number - TC-MDP-1223-01886
Inspection Description - COT - RSBU - Exterior Clips/SheathingÂ
Inspection Status - Passed
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/29/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | Exterior and interior walls are properly secured to concrete floor with shot pins, j-bolts, titan bolts, or masa clips. Plywood sheathing is installed and secured to studs per plan requirements for shear walls. Shear wall hold downs are installed with the required nails in plate and bolted through bottom plate with a titan bolts. Okay to proceed with mechanical, electrical, and plumbing rough-in. |