Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 141460580


Addresses:

9677 E HARKES DR


Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Permit Number - TC-MDP-1223-01886

Inspection Description - COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
10/10/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required Revision is being sent in for the two houses (right of home) for multiple switches called out on the plans and not installed in field. Exhaust fan in laundry room not wired. Add nail plate to range line and any electrical line that is less than an 1 1/4". ABS line in great room area has been punctured with staples. Block off any opening through floor cavities. 10/7/2024
10/21/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 10/21/24: All items noted on last inspection have been corrected. Okay to proceed with installation of insulation and drywall.