Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-MDP-1223-01857

Parcel: 129140400

Inspection Status: Passed

Inspection History: COT - RSPL - Sewer 

Date Description Inspector Results Comments
02/13/2024 COT - RSPL - Sewer  Passed 2/13/24: P3003.13.4 Plastic pipe or tubing to other piping material. Joints between different types of plastic pipe shall be made with approved adapter fitting or by a solvent cement joint only where a single joint is made between ABS and PVC pipes at the end of a building drainage pipe and the beginning of a building sewer pipe using a solvent cement complying with ASTM D3138. Multiple joints were made between ABS and PVC.
2/13/24: corrections made ok to backfill.
05/16/2024 COT - RSPL - Sewer  Passed