Inspection History Details
Inspection Status: Passed
Inspection History: COT - RSPL - Sewer
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/13/2024 | COT - RSPL - Sewer | Passed | 2/13/24: P3003.13.4 Plastic pipe or tubing to other piping material. Joints between different types of plastic pipe shall be made with approved adapter fitting or by a solvent cement joint only where a single joint is made between ABS and PVC pipes at the end of a building drainage pipe and the beginning of a building sewer pipe using a solvent cement complying with ASTM D3138. Multiple joints were made between ABS and PVC. 2/13/24: corrections made ok to backfill. |
|
| 05/16/2024 | COT - RSPL - Sewer | Passed |