Inspection Status: Not Ready

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - TC-MDP-1222-00150

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Not Ready

Date Description Inspector Results Comments
03/06/2023 COT - RSBU - Exterior Clips/Sheathing  Not Ready Workers still in house, not ready for inspection
03/07/2023 COT - RSBU - Exterior Clips/Sheathing  Not Ready Not ready. Missing shear wall 1st floor. Shear wall in great room in the wrong place. Add continuous studs for double truss. Nailing schedule on shear walls need to be completed. Nail every 16” on all perimeter in second floor bottom plate. Missing rsp clips on studs and headers.
03/10/2023 COT - RSBU - Exterior Clips/Sheathing  Passed Approved. Corrections were made. 3/10/2023