Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Inspection Status: Not Ready

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
03/06/2023 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Not Ready Workers still in house, not ready for inspection
03/07/2023 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Not Ready Not ready. Missing shear wall 1st floor. Shear wall in great room in the wrong place. Add continuous studs for double truss. Nailing schedule on shear walls need to be completed. Nail every 16” on all perimeter in second floor bottom plate. Missing rsp clips on studs and headers.
03/10/2023 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed Approved. Corrections were made. 3/10/2023