Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-MDP-1124-01341

Parcel: 137042060


Addresses:

5405 S IDA LN

Inspection Status: Passed

Inspection History: COT - RSEL - Outdoor Lighting

Date Description Inspector Results Comments
01/13/2026 COT - RSEL - Outdoor Lighting Passed
12/18/2025 COT - RSEL - Outdoor Lighting Re-inspection required 12/18/25: WR receptacle required at exterior receptacle, GFCI protection required at garage, cracked roof tiles please replace, broken roof tiles 2nd floor, AFCI required at garbage disposal/dishwasher, grade must be corrected, WR receptacle required outdoors, GFCI receptacle required at laundry room, water hammer arrestor shall not be painted, mark air handler to verify correct amperage at disconnect box, verify condensate pump to be tied into air handler, secure electrical riser at main panel, insulate hot water line at water heater, post tension tag required at hose bib, roof drain must be re-routed pending on 5409, clean-outs caps at garage and grade must be opened,
12/19/2025 COT - RSEL - Outdoor Lighting Not Ready