COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required 4 MAR 25

1. EV charger is on 10 AWG copper, needs to be on 6 AWG or thicker.
2. FHA plate needed on hvac supply flex in 1st bedroom on the right 2nd floor.
3. FHA PLATE on Vent in upstairs middle bathroom needs to extend minimum of 2" below top plate.
4. HVAC refrigerant lines on the second floor above ceiling needs to be supported.
5. HVAC air supply lines flex , 1st flr laundry room above top plate needs to be separated from dryer exhaust vent.
03/05/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 3/5/25 corrections made