Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Permit Number - TC-MDP-1124-01312

Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
06/18/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required Plans call for x2 2x10 at covered porch. Loose anchor bolts throughout. Add shot pins 6” from edges and two pins required at bottom plate being greater than 12”. In office area ledgers is the incorrect size. Plans state 10’ 1” or greater ledger size should be 2x8. Stopped inspection. Other items may occur. 6/18/2025
06/26/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 6/26/25 corrections made