Parcel: 141460300


Addresses:

9532 E HARKES DR


Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Roof Nailing 

Permit Number - TC-MDP-1124-01312

Inspection Description - COT - RSBU - Roof Nailing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
06/18/2025 COT - RSBU - Roof Nailing  Re-inspection required Plans call for x2 2x10 at covered porch. Loose anchor bolts throughout. Add shot pins 6” from edges and two pins required at bottom plate being greater than 12”. In office area ledgers is the incorrect size. Plans state 10’ 1” or greater ledger size should be 2x8. Stopped inspection. Other items may occur. 6/18/2025
06/26/2025 COT - RSBU - Roof Nailing  Re-inspection required 6/26/25 loose roofing in 3 marked areas south side of house 2nd floor
07/02/2025 COT - RSBU - Roof Nailing  Passed 7/2/25 passed