Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Canceled
Inspection History: COT - RSBU - Roof Nailing
Permit Number - TC-MDP-1124-01290
Inspection Description - COT - RSBU - Roof Nailing
Inspection Status - Canceled
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/01/2025 | COT - RSBU - Roof Nailing | Canceled | Canceled per Duke. 7/1/2025 | |
| 07/02/2025 | COT - RSBU - Roof Nailing | Re-inspection required | Not ready. Missing h25 throughout. Missing pins at all interior bottom plates. Htt4 not nailed in place. Add a35 clips above shear wall in garage. Stopped inspection. Other items may apply. 7/2/2025 | |
| 07/07/2025 | COT - RSBU - Roof Nailing | Re-inspection required | 7.7.25 Shot pins required 6 inch from edge of sole plate throughout on (non load bearing). Install anchor bolts as marked, locations, Anchor bolts required within 12" of edge of exterior sole plates. A35s missing nails in multiple areas. RSP 4s required every other stud-add to marked locations, add h-25 at truss CG48C, loose roof panel on bedroom located on south-side. |
|
| 07/09/2025 | COT - RSBU - Roof Nailing | Passed | 7-9-25: roof nailing approved |