Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Canceled

Inspection History: COT - RSBU - Roof Nailing 

Permit Number - TC-MDP-1124-01290

Inspection Description - COT - RSBU - Roof Nailing 

Inspection Status - Canceled

Date Description Inspector Results Comments
07/01/2025 COT - RSBU - Roof Nailing  Canceled Canceled per Duke. 7/1/2025
07/02/2025 COT - RSBU - Roof Nailing  Re-inspection required Not ready. Missing h25 throughout. Missing pins at all interior bottom plates. Htt4 not nailed in place. Add a35 clips above shear wall in garage. Stopped inspection. Other items may apply. 7/2/2025
07/07/2025 COT - RSBU - Roof Nailing  Re-inspection required 7.7.25
Shot pins required 6 inch from edge of sole plate throughout on (non load bearing). Install anchor bolts as marked, locations, Anchor bolts required within 12" of edge of exterior sole plates. A35s missing nails in multiple areas. RSP 4s required every other stud-add to marked locations, add h-25 at truss CG48C, loose roof panel on bedroom located on south-side.
07/09/2025 COT - RSBU - Roof Nailing  Passed 7-9-25: roof nailing approved