Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/18/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 9-18-25: add nails to all shear walls-nails can be no closer than 3/8” from joints and cannot over penetrate more than 1/16”. Add RSP4’s to stud at southside, add shot pins and anchor bolts to marked locations, add H25 to truss CG48C, missing gable bracing at back patio-see SD3/7 for details. | |
| 09/22/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 9/22/25 1. RSP still missing 2. Missing shot pins near bathroom sill. |
|