Inspection Status: Partial Pass
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Permit Number - TC-MDP-1124-01267
Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Inspection Status - Partial Pass
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/02/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Partial Pass | 1-Add hold down to bolt near outside of garage wall in lieu of running shear to outside. 2-Add bolt missing at garage. 3-Add RSP4s where marked. Will look at Intermediate. |
|
| 09/04/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed |