Parcel: 140364030


Addresses:

6481 S AMBARELLA DR


Inspection Status: Canceled

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - TC-MDP-1123-01831

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Canceled

Date Description Inspector Results Comments
06/27/2024 COT - RSBU - Exterior Clips/Sheathing  Canceled Canceled per contractor. 6/27/2024
06/28/2024 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required Covered patio ledgers call for (4) 16 D nails every 16" o.c. Rafters call to be every 16" o.c. Missing anchor bolts at ends of bottom plates and behind shear walls. Secure 2x6 stud at master bedroom. Add 2x6 stud in first bathroom. Add straps from beams to studs. 6/28/2024
07/03/2024 COT - RSBU - Exterior Clips/Sheathing  Canceled Canceled per contractor. 7/3/2024
07/10/2024 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required (with fee) Per previous notes . 7/10/2024
07/26/2024 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required (with fee) Ledger at covered patio still missing nails. Still missing 2x6 at bathroom, anchor bolts that have been hammered into placed need to be replaced with proper installation. Proceed to intermediate with approval of framing. 7/26/2024
Canceled per contractor. 7/3/2024

Per previous notes . 7/10/2024
07/30/2024 COT - RSBU - Exterior Clips/Sheathing  Passed