07/25/2024 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | 7/25/24: missing anchor bolts where excessive masa clips legs are up. Anchor bolts not to schedule at shear wall 11. Cut nails needed at master bathroom. | |
07/29/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | 7/29/24: Titanic Anchor bolts have been installed where excessive masa clip legs were attached to studs and not to base plate. Titan bolts installed on shear wall 11. Shot pins installed in base plate at master bathroom wall. Okay to proceed with rough-in. |