Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior Clips/Sheathing
Permit Number - TC-MDP-1123-01824
Inspection Description - COT - RSBU - Exterior Clips/Sheathing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/30/2024 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | 1/30/24: missing nailing at rsp clips. Missing nailing at shear wall in garage. Missing anchor bolt at shear | |
02/02/2024 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | 2/2/24: missing nailing at rsp clips. Missing anchor bolt at shear wall. | |
02/05/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | 2/5/24: all corrections made |