Inspection Status: Re-inspection required

Inspection History: COT - RSEL - Outdoor Lighting

Permit Number - TC-MDP-1123-01798

Inspection Description - COT - RSEL - Outdoor Lighting

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
10/02/2024 COT - RSEL - Outdoor Lighting Re-inspection required 10/2/24: post tension tag required at hose bib, properly coat all plastic piping on exterior of house, weep screed clearance not met, 3" clearance required from grade to A/C condenser, water hammer arrestor must have visible listings, no ladder for attic access, provide plans at final inspection, b-vent must be taped at single wall pipe,
10/09/2024 COT - RSEL - Outdoor Lighting Passed APPROVED. 10/9/2024