Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Permit Number - TC-MDP-1123-01717
Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/14/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 3/14/24: shear wall missing anchor bolt. must be within 12 inches of end of shear inside shear wall. missing blocking at jack to girder trust front and back of house. | |
| 03/18/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed |