Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/13/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | 7/13/26: NOT READY | |
| 07/14/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required (with fee) | 7-14-26: block register northeast bedroom, secure DWV adjacent to tub, add clamp or strap to secure hot pex line, add strap to laundry exhaust, add strap to laundry DWV-10' vertical maximum, missing back pour behind DWV at tub, seal penetrations throughout at south & north vapor barrier, a receptacle is required within 6' of a door opening at master bedroom, insulate hot pex lines, install a Boca plate to protect AWG wires at entryway- lower half of nail plates installed are not nailed to top plate. | |
| 07/15/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 07/15/2026 Corrections made to prior inspection. |