Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
11/19/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 11.19.2025
Missing HTT5’s at SW13 along with steel washer plates on anchor bolts, missing washer plates at all SW11 shear walls, add A35 clips to interior garage shear wall after roof loaded, provide engineer letter/fix on truss A3B near west side of where mechanical trusses start.
11/20/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 11.20.2025
All corrections made. Engineer letter and fix completed.