Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-MDP-1024-01251

Parcel: 137041930


Addresses:

5416 S IDA LN

Inspection Status: Partial Pass

Inspection History: COT - RSBU - Roof NailingĀ 

Date Description Inspector Results Comments
01/29/2025 COT - RSBU - Roof NailingĀ  Partial Pass 1-29-25, contractor requested that I only inspect exterior sheathing, shear walls, anchor bolts , and roof nailing on each property. Add anchor bolts to marked areas together with HTT4's where outlined in approved plans. Roof nailing approved-okay to dry in (truss bracing still needs to be inspected) Partial pass on exterior sheathing because section above garage was missing. Okay to continue construction at progress areas. Items requiring correction will be verified at interior framing inspection.
02/14/2025 COT - RSBU - Roof NailingĀ  Passed 2/14/25 corrections made ok to proceed to intermediate