| 01/09/2026 | ENGR Engineering Final | Not Ready | 01/09/26 Accessible route- sidewalk has more than 1/2" vertical separation to finish floor at doorway. Thresholds in doorways are over 1/2" Driveway parking space needs to be graded at no more than 2% slope both ways and compacted. This space needs to at the same grade as the accessible route. |
|
| 01/13/2026 | ENGR Engineering Final | Passed |