Inspection History Details
Inspection Status: Re-inspection required
Inspection History: RSBU - Building Final
Permit Number - TC-MDP-1024-01197
Inspection Description - RSBU - Building Final
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/28/2025 | RSBU - Building Final | Re-inspection required | 4/28/25: Clearance at A/C condenser unit 3" required from grade, noalax required at A/C conductors in disconnect, GFCI at garage required, cut back clean-out in bedroom and cap, A.A.V missing at kitchen island, missing clean-out at master bedroom, cut gray water clean out to grade, wiring at kitchen/dinning not per plan, thermostat must be no higher than 48" A.F.F, provide proper ladder for attic access. | |
| 04/30/2025 | RSBU - Building Final | Passed |