Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Re-inspection required

Inspection History: COT - RSME - Mechanical Final 

Permit Number - TC-MDP-1024-01197

Inspection Description - COT - RSME - Mechanical Final 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
04/28/2025 COT - RSME - Mechanical Final  Re-inspection required 4/28/25: Clearance at A/C condenser unit 3" required from grade, noalax required at A/C conductors in disconnect, GFCI at garage required, cut back clean-out in bedroom and cap, A.A.V missing at kitchen island, missing clean-out at master bedroom, cut gray water clean out to grade, wiring at kitchen/dinning not per plan, thermostat must be no higher than 48" A.F.F, provide proper ladder for attic access.
04/30/2025 COT - RSME - Mechanical Final  Passed