Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
04/04/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 4 April 25
1. Damaged sill plate behind bathtub, please add anchor bolts no closer than 3.5 inches for 1/2 and 4.5 inches for 5/8 AB.
2. Shot pins needed throughout marked with an x with circle around it. Do not use cut nails.
3. Truss CG48C, per plan requires H2.5 on the bottom chord.
04/08/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 8 April 25
Truss CG48C per plan requires H2.5 on the bottom chord.
04/10/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 4/10/2025 corrections were made.