Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Permit Number - TC-MDP-1024-01184
Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 3-24-25, p-1 shear wall at outside of bedroom 3-add nails to marked areas where nailing is over penetrated together with some nails not being nailed flush to sheathing, nail down a-35's at garage and throughout, Foyer area "do not splice top plate" of truss bearing wall, add washers to anchor bolts at column together with shot pins. | ||
| 03/26/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 3/26/25 corrections made |