Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 133571540


Addresses:

264 N SUNNY COVE PL


Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Permit Number - TC-MDP-1024-01184

Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 3-24-25, p-1 shear wall at outside of bedroom 3-add nails to marked areas where nailing is over penetrated together with some nails not being nailed flush to sheathing, nail down a-35's at garage and throughout, Foyer area "do not splice top plate" of truss bearing wall, add washers to anchor bolts at column together with shot pins.
03/26/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 3/26/25 corrections made