Parcel: 141460560


Addresses:

7430 S KELLER LN


Inspection Status: Passed

Inspection History: COT - RSEL - Electrical Underground 

Permit Number - TC-MDP-1023-01709

Inspection Description - COT - RSEL - Electrical Underground 

Inspection Status - Passed

Date Description Inspector Results Comments
04/19/2024 COT - RSEL - Electrical Underground  Passed Concrete forms are set, post tension cabling is in place, rebar reinforcement is installed per plans, UFER Ground is in place, shear wall hold downs are in place per plans, masa clips are properly installed, underground electrical for kitchen island is in place, and all underground plumbing pipes are properly wrapped with foam wrap. Okay to pour concrete for slab and footings.