Inspection Status: Passed
Inspection History: COT - RSEL - Electrical Underground
Permit Number - TC-MDP-1023-01706
Inspection Description - COT - RSEL - Electrical Underground
Inspection Status - Passed
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/29/2024 | COT - RSEL - Electrical Underground | Passed | Concrete forms are set, post tension cabling is installed per plans and passed 3rd party inspection, rebar reinforcement is installed per plans, masa clips are properly spaced and secured to edge of form, shear wall clips are secured to form and in their proper location, all underground plumbing pipes are properly wrapped with foam to protect from damage, and underground electrical is properly installed for kitchen island. Okay to pour concrete for footings and slab. |