Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 141462100


Addresses:

7415 S KELLER LN


Inspection Status: Passed

Inspection History: COT - RSEL - Grounding/BondingĀ 

Permit Number - TC-MDP-1023-01706

Inspection Description - COT - RSEL - Grounding/BondingĀ 

Inspection Status - Passed

Date Description Inspector Results Comments
04/29/2024 COT - RSEL - Grounding/BondingĀ  Passed Concrete forms are set, post tension cabling is installed per plans and passed 3rd party inspection, rebar reinforcement is installed per plans, masa clips are properly spaced and secured to edge of form, shear wall clips are secured to form and in their proper location, all underground plumbing pipes are properly wrapped with foam to protect from damage, and underground electrical is properly installed for kitchen island. Okay to pour concrete for footings and slab.