Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Permit Number - TC-MDP-1023-01702

Inspection Description - COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
11/12/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required 11-12-24, metal pancake box for exterior light near garage is overfilled. Box contains to 14/2 awg and is rated for 6 cubic inches, shower upstairs not under test, seal staples at vapor barrier in bedroom 2.
11/14/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Partial Pass 11-14-24. Items from previous inspection made. Okay to proceed at own risk. Electrical not per approved plans. Provide a letter from Austin electric together with a schematic of electrical layout. These items must be submitted, reviewed and approved by the city prior to a certified of occupancy can be issued.