Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Roof Nailing
Permit Number - TC-MDP-1023-01702
Inspection Description - COT - RSBU - Roof Nailing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/01/2024 | COT - RSBU - Roof Nailing | Re-inspection required | Missing studs for continuous loads. Missing studs underneath GT. Loose shear walls throughout. Add cs16 straps to top plates that meet but are not secured to each other. Provide 1 titan at marked area. 2nd floor bottom plates interior and shear walls are not nailed per schedule. 8/1/2024 | |
08/06/2024 | COT - RSBU - Roof Nailing | Re-inspection required | 8/6/24: no plans | |
08/07/2024 | COT - RSBU - Roof Nailing | Canceled | 8/7/24: Cancelled by contractor. Items above are not completed. | |
COT - RSBU - Roof Nailing | Passed |