Inspection Status: Passed
Inspection History: COT - RSEL - Grounding/BondingĀ
Permit Number - TC-MDP-1023-01701
Inspection Description - COT - RSEL - Grounding/BondingĀ
Inspection Status - Passed
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/03/2024 | COT - RSEL - Grounding/BondingĀ | Passed | Concrete forms are set, post tension cabling is properly installed per plans, Simpson clips are properly installed and secured to form work per plans, all plumbing pipes are properly wrapped with foam padding, and 20' rebar is placed in footing for Ufer ground. Okay to pour concrete. |