Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
03/06/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 3/6/24: M.A.S.A. Clips spacing greater than 6' at multiple locations (add anchor bolts), spalling at STHD 14 at garage greater than 4" will need RFI on replacement, Shear wall fastening schedule at back porch not per schedule. H2.5 clip missing throughout. HTT4 not in place at time of inspection at garage shear wall.
03/14/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Partial Pass HTT missing nails, over spalled hold-down at front of garage. Partial-pass.
05/08/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed