Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-MDP-1023-01629

Parcel: 126181240


Addresses:

4013 E 22ND ST

Inspection Status: Re-inspection required

Inspection History: COT - RSPL - Rough Soil 

Date Description Inspector Results Comments
10/30/2023 COT - RSPL - Rough Soil  Re-inspection required 10/30/23: two way clean out missing at sewer connection to first duplex, rough plumb water testing shall be tested to a point no less then 5ft or from the highest point in the completed system. (P2503.5.1)
10/31/2023 COT - RSPL - Rough Soil  Passed