Parcel: 126181240


Addresses:

4013 E 22ND ST


Inspection Status: Re-inspection required

Inspection History: COT - RSPL - Rough Soil 

Permit Number - TC-MDP-1023-01629

Inspection Description - COT - RSPL - Rough Soil 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
10/30/2023 COT - RSPL - Rough Soil  Re-inspection required 10/30/23: two way clean out missing at sewer connection to first duplex, rough plumb water testing shall be tested to a point no less then 5ft or from the highest point in the completed system. (P2503.5.1)
10/31/2023 COT - RSPL - Rough Soil  Passed