Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date |
Description |
Inspector |
Results |
Comments |
| 07/11/2024 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Re-inspection required |
2x6 at entry needs to be replaced so that it's continues. Loose shear wall at garage entry and family room. Htt4 needs to be set in place and nailed. Beam post need to be clipped to bottom plates. Add anchor bolts to follow shear schedule. 2x6 ballon frame needs to be replaced. Add a35 clips underneath landing. Add blocking in between stairs. Nailing at bottom plate perimeter not per schedule. House has been walked by framers but items haven't been taken care of. Stopped inspection. 7/11/2024 |
| 07/16/2024 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Re-inspection required |
Per previous notes. 7/16/2024 |
| 07/19/2024 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Re-inspection required |
7/19/24: Add blocking in between stairs.Loose shear wall at garage entry and family room.2nd floorNailing at bottom plate perimeter not per schedule. |
| 07/30/2024 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Re-inspection required (with fee) |
Per previous notes. 7/30/2024 |
| 08/05/2024 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Re-inspection required |
Per previous notes. 8/5/2025 |
| 08/09/2024 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Passed |
Corrections were made. 8/9/2024 |