Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 141431990


Addresses:

6819 E PASEO BERCEO


Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Roof Nailing 

Permit Number - TC-MDP-1023-01595

Inspection Description - COT - RSBU - Roof Nailing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
07/11/2024 COT - RSBU - Roof Nailing  Re-inspection required 2x6 at entry needs to be replaced so that it's continues. Loose shear wall at garage entry and family room. Htt4 needs to be set in place and nailed. Beam post need to be clipped to bottom plates. Add anchor bolts to follow shear schedule. 2x6 ballon frame needs to be replaced. Add a35 clips underneath landing. Add blocking in between stairs. Nailing at bottom plate perimeter not per schedule. House has been walked by framers but items haven't been taken care of. Stopped inspection. 7/11/2024
07/16/2024 COT - RSBU - Roof Nailing  Re-inspection required Per previous notes. 7/16/2024
07/19/2024 COT - RSBU - Roof Nailing  Re-inspection required 7/19/24: Add blocking in between stairs.Loose shear wall at garage entry and family room.2nd floorNailing at bottom plate perimeter not per schedule.
07/30/2024 COT - RSBU - Roof Nailing  Re-inspection required
08/05/2024 COT - RSBU - Roof Nailing  Re-inspection required
08/09/2024 COT - RSBU - Roof Nailing  Passed