Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Roof Nailing
Permit Number - TC-MDP-1023-01595
Inspection Description - COT - RSBU - Roof Nailing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/11/2024 | COT - RSBU - Roof Nailing | Re-inspection required | 2x6 at entry needs to be replaced so that it's continues. Loose shear wall at garage entry and family room. Htt4 needs to be set in place and nailed. Beam post need to be clipped to bottom plates. Add anchor bolts to follow shear schedule. 2x6 ballon frame needs to be replaced. Add a35 clips underneath landing. Add blocking in between stairs. Nailing at bottom plate perimeter not per schedule. House has been walked by framers but items haven't been taken care of. Stopped inspection. 7/11/2024 | |
07/16/2024 | COT - RSBU - Roof Nailing | Re-inspection required | Per previous notes. 7/16/2024 | |
07/19/2024 | COT - RSBU - Roof Nailing | Re-inspection required | 7/19/24: Add blocking in between stairs.Loose shear wall at garage entry and family room.2nd floorNailing at bottom plate perimeter not per schedule. | |
07/30/2024 | COT - RSBU - Roof Nailing | Re-inspection required | ||
08/05/2024 | COT - RSBU - Roof Nailing | Re-inspection required | ||
08/09/2024 | COT - RSBU - Roof Nailing | Passed |