Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-MDP-0925-00596

Parcel: 141460920


Addresses:

9556 E FRIEDEL DR

Inspection Status: Not Ready

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
07/30/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Not Ready Add nails to belly bands 3” o.c . Add studs to marked areas per girder layout. Add screws to truss j13 at front porch. Add 2’ shear at front entry. Add staples to t ply. 3” o.c. Add screw to 4 ply truss in garage. Add nails to hangers at GT near garage door. Plans call for 4 kings at garage opening. Provide 2x blocking per note 1 at garage area. Add shot pins to marked areas. Loose shear at second floor. Flush screws to truss at marked areas total (3). Provide hanger at jo1. 7/30/2026
08/05/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 8-5-26: corrections made-exterior clip/ sheathing/framing approved.